15323 a2c96a390803b164 3.6(a)(2)(12)   0 PRIMARY ENCLOSURES. The outside wire runs of the Stacker building that are coated with a material (plastic/fiberglass/rubber, etc.) have numerous missing pieces of the material, leaving bare wire that is not adequate flooring for dogs to walk on. Metal strands of wire used for flooring must be greater than 1/8 of an inch in diameter (9 gauge) or coated. These missing pieces of coating leave the wire flooring less that 9 gauge. This flooring must be repaired or replaced. This will help ensure that the dogs in this building are on flooring that will allow them to move around comfortable and be injury free. Correct by 10-09-2014.